Cisco AJ732A - MDS 9134 Fabric Switch Messages Manual page 261

Cisco mds 9000 family system messages reference (ol-15956-01, april 20078)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 2
System Messages and Recovery Procedures for the Cisco MDS 9000 Family
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Error Message PLATFORM-2-PS_CAPACITY_DIFFER: Detected power supplies with differing
capacity. It is recommended to have same capacity for both powersupplies otherwise
it may cause service disruptions.
Error Message PLATFORM-2-PS_DETECT: Power supply [dec] detected but shutdown (Serial
number [chars]).
Error Message PLATFORM-2-PS_FAIL: Power supply [dec] failed or shutdown (Serial No.
[chars]).
Error Message
Error Message PLATFORM-2-PS_FANOK: Fan in Power supply [dec] ok.
OL-15956-01
Explanation
Detected a power supply that has a different capacity than an the other power supply.
Refer tot he Cisco MDS 9000 Family CLI Configuration Guide for information
Recommended Action
on increasing or decreasing power supply capacity and configuring power supplies. Use the show
environment power and show platform internal info to collect more information.
Introduced
Cisco MDS SAN-OS Release 3.0(1).
Power Supply is detected but has been shut down.
Explanation
Use the CLI commands show environment power and show platform
Recommended Action
internal info to collect more information, or use similar Fabric Manager procedures.
Cisco MDS SAN-OS Release 3.0(1).
Introduced
Explanation
Power supply failed or has been shut down.
Enter the show environment power and show platform internal info CLI
Recommended Action
command or use a similar Fabric Manager or Device Manager procedure to collect more
information. See the power supply documentation in the relevant hardware installation guide to learn
more on increasing or decreasing power supply capacity and configuring power supplies.
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
PLATFORM-2-PS_FANFAIL: Fan in Power supply [dec] failed.
Explanation
Fan module in the named power supply has failed.
Enter the show environment power and show platform internal info CLI
Recommended Action
command or use a similar Fabric Manager/Device Manager procedure to collect more information.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
Explanation
Fan module in the named power supply is operating.
No action is required.
Recommended Action
Cisco MDS SAN-OS Release 3.0(1).
Introduced
Cisco MDS 9000 Family System Messages Reference
2-225

Advertisement

Table of Contents
loading

Table of Contents