Chapter 2
System Messages and Recovery Procedures for the Cisco MDS 9000 Family
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Error Message MODULE-4-XBAR_WARNING: Xbar [dec] (serial: [chars]) reported warnings
on ports [dec]/[dec]-[dec]/[dec] ([chars]) due to [chars] in device [dec] (device
error [hex]).
MODULE-5
Error Message
Error Message
[dec]/[dec]-[dec]/[dec] ([chars]) due to [chars] in device [dec] (error [hex]).
Error Message MODULE-5-MOD_OK: Module [dec] is online (serial: [chars]).
Error Message MODULE-5-MOD_MINORSWFAIL: Module [dec] reported a failure in service
[chars].
OL-15956-01
Explanation
Xbar reported a warning in the runtime diagnostic because of failure in some of the
ports.
Collect information about the module by issuing the show module internal
Recommended Action
all xbar [decimaldigit] CLI command or by using a similar Fabric Manager procedure.'
Introduced
Cisco MDS SAN-OS Release 3.0(1).
MODULE-5-ACTIVE_SUP_OK: Supervisor [dec] is active.
Module is ready to be configured and to switch traffic.
Explanation
No action is required.
Recommended Action
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
MODULE-5-MOD_DIAG_FAIL: Module [dec] reported failure on ports
The module in the slot reported a failure in the runtime diagnostic. Module manager
Explanation
will power cycle the module.
Collect module information by entering the show module internal all module
Recommended Action
[dec] command or by using a similar Fabric Manager procedure.
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
Cisco MDS SAN-OS Release 2.0(1b).
Deprecated
Module named is ready to be configured and to switch traffic.
Explanation
No action is required.
Recommended Action
Cisco MDS SAN-OS Release 3.0(1).
Introduced
A non-critical failure caused by the service occurred in the module. The module will
Explanation
not be reset.
Collect module information by entering the show module internal all module
Recommended Action
[dec] command or by using a similar Fabric Manager procedure.
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
Cisco MDS 9000 Family System Messages Reference
2-201