Platform-3 - Cisco AJ732A - MDS 9134 Fabric Switch Messages Manual

Cisco mds 9000 family system messages reference (ol-15956-01, april 20078)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Error Message
idprom read error.
Error Message
Error Message PLATFORM-3-XBAR_PWRFAIL: Xbar [dec] failed to power up (Serial number
[chars]).
Error Message PLATFORM-3-XBAR_PWRIDPROMFAIL: Xbar [dec] failed to power up due to
IDPROM read error.
PLATFORM-4
Error Message PLATFORM-4-MOD_TEMPFAIL: [chars] temperature sensor [dec] failed.
Cisco MDS 9000 Family System Messages Reference
2-228
PLATFORM-3-MOD_PWRIDPROMFAIL: Module [dec] failed to power up due to
The module cannot be powered up because of an IDPROM read error.
Explanation
Enter the show platform internal all module [dec] and show module
Recommended Action
internal all module [dec] show sprom module [dec][dec] CLI commands or use similar Fabric
Manager/Device Manager procedures to collect more information.
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
PLATFORM-3-SYS_IDPROMBAD:
The chassis IDPROM contains invalid data.
Explanation
Enter the show sprom module [dec] CLI command or use a similar Fabric
Recommended Action
Manager/Device Manager procedure to read module idprom contents and collect more information.
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
The named xbar in the slot failed to power up.
Explanation
Recommended Action
Use the show platform internal all module [decimaldigit] CLI command to
collect more information or use a similar Fabric Manager procedure.
Cisco MDS SAN-OS Release 3.0(1).
Introduced
The xbar named cannot be powered up because of an IDPROM read error.
Explanation
Use the CLI commands show platform internal all module [decimaldigit]
Recommended Action
and show module internal all module [decimaldigit] and show sprom xbar [dec] [dec] to read
module IDPROM contents to collect more information (or use a similar Fabric Manager procedure).
Cisco MDS SAN-OS Release 3.0(1).
Introduced
Explanation
The module in the slot named contains a faulty temperature sensor.
Use the show env temperature CLI command to collect more information or
Recommended Action
use a similar Fabric Manager procedure.
Cisco MDS SAN-OS Release 3.0(1).
Introduced
Chapter 2
System Messages and Recovery Procedures for the Cisco MDS 9000 Family
Chassis idprom [dec] data invalid.
OL-15956-01

Advertisement

Table of Contents
loading