P Commands
•
This command does not require a license.
Examples
This example shows how to configure the power supply redundancy mode:
switch# config t
switch(config)# power redundancy-mode ps-redundant
This example shows how to disable the power supply redundancy mode:
switch# config t
switch(config)# no power redundancy-mode ps-redundant
Related Commands
Command
show environment
power
OL-25806-03
Full redundancy mode—This mode combines power supply redundancy and input source
redundancy, which means that the chassis has an extra power supply and one half of each power
supply is connected to one electrical grid while the other half of each power supply is connected to
the other electrical grid. The available power is the lesser of the available power for power supply
redundancy mode and input source redundancy mode.
Description
Displays information about the power capacity and power distribution of
the system.
Cisco Nexus 7000 Series NX-OS System Management Command Reference
power redundancy-mode
329