Event Oir - Cisco Nexus 7000 Series Reference Manual

Nx-os system management command reference
Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

event oir

event oir
To specify that an Embedded Event Manager (EEM) applet be run on the basis of an event raised when
a hardware online insertion and removal (OIR) occurs, use the event oir command. This command has
three forms; fan, module, and powersupply. To remove the OIR specification from the configuration,
use the no form of this command.
Syntax Description
tag tag
fan
module
powersupply
insert
remove
anyoir
number
Defaults
None
Command Modes
Embedded event manager
Supported User Roles
network-admin
vdc-admin
Command History
Release
5.2.(1)
4.0(1)
Usage Guidelines
This command does not require a license.
Cisco Nexus 7000 Series NX-OS System Management Command Reference
160
event oir [tag tag] {fan | module | powersupply} {insert | remove | anyoir} [number]
no event oir [tag tag] {fan | module | powersupply} {insert | remove | anyoir} [number]
(Optional) Identifies this specific event when multiple events are included in the
policy.
Specifies the system fans. Optionally, specify an individual fan.
Specifies the system modules. Optionally, specify an individual module.
Specifies the system power supplies. Optionally, specify an individual power
supply.
Specifies to insert OIR.
Specifies to remove OIR.
Specifies to either insert or remove OIR.
(Optional) If you selected fan, enter a fan number to monitor for an OIR event.
The range is from 1 to 4. If you selected module, enter a module number to
monitor for an OIR event. The range is from 1 to 10. If you selected powersupply,
enter a power supply number to monitor for an OIR event. The range is from 1 to
3.
Modification
Added the tag tag keywords.
This command was introduced.