diagnostic monitor interval module

diagnostic monitor interval module
To configure a diagnostic monitoring test interval on a module, use the diagnostic monitor interval
module command. To remove the diagnostic monitoring test interval, use the no form of this command.
Syntax Description
module
test
all
name
test-id
hour
hour
min
min
second
sec
Defaults
None
Command Modes
Global configuration mode (config)
Supported User Roles
network-admin
vdc-admin
Command History
Release
4.0(1)
Usage Guidelines
This command does not require a license.
Examples
This example shows how to configure a diagnostic monitoring test interval on a module:
switch(config)# diagnostic monitor interval module 1 test 5 hour 10 min 30 sec 0
switch(config)#
This example shows how to remove a diagnostic monitoring test interval from a module:
Cisco Nexus 7000 Series NX-OS System Management Command Reference
122
diagnostic monitor interval module module test {all | name | test-id} hour hour min min second
sec
no diagnostic monitor interval module module test {all | name | test-id}
Module number.
Specifies a diagnostic test.
Specifies all test IDs.
Test name.
Test ID number.
Specifies the hour of the interval that the test begins.
Hour of the interval that you specify to start the test.
Specifies the minute of the interval that the test begins.
Minute of the interval that you specify to start the test.
Specifies the second of the interval that the test begins.
Second of the interval that you specify to start the test.
Modification
This command was introduced.
D Commands