Cisco AP775A - Nexus Converged Network Switch 5010 Configuration Manual page 533

Fabric manager configuration guide, release 4.x
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

Chapter 23
Configuring PortChannels
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Figure 23-12
Change the channel ID or description for each switch, if necessary.
Step 9
Review the attributes at the bottom of the screen, and set them if applicable.
Step 10
The following attributes are shown in
VSAN List—This gives a list of VSANs to which the ISLs belong.
Trunk Mode—You can enable trunking on the links in the PortChannel. Select trunking if your link
is between TE ports. Select nontrunking if your link is between E ports. Select auto if you are not
sure.
Force Admin, Trunk, Speed, and VSAN attributes to be identical—This check box ensures that the
same parameter settings are used in all physical ports in the channel. If these settings are not
identical, the ports cannot become part of the PortChannel.
Speed—The port speed values are auto, 1Gb, 2Gb, 4Gb, 8Gb, autoMax2G, and autoMax4G.
Click OK.
Step 11
The PortChannel is created. Note that it may take a few minutes before the new PortChannel is visible
in the Fabric pane.
OL-17256-03, Cisco MDS NX-OS Release 4.x
Create a PortChannel
Figure
Cisco MDS 9000 Family Fabric Manager Configuration Guide
23-12:
PortChannel Configuration
23-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents