Configuring The Rscn Timer With Cfs; Default Settings - Cisco AP775A - Nexus Converged Network Switch 5010 Configuration Manual

Fabric manager configuration guide, release 4.x
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

Default Settings

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Before performing a downgrade, make sure that you revert the RCSN timer value in your network to the
Note
default value. Failure to do so will disable the links across your VSANs and other devices.
Compatibility across various Cisco MDS NX-OS releases during an upgrade or downgrade is supported
by conf-check provided by CFS. If you attempt to downgrade from Cisco MDS SAN-OS Release 3.0,
you are prompted with a conf-check warning. You are required to disable RSCN timer distribution
support before you downgrade.
By default, the RSCN timer distribution capability is disabled and is therefore compatible when
upgrading from any Cisco MDS SAN-OS release earlier than Release 3.0.

Configuring the RSCN Timer with CFS

To configure the RSCN timer with CFS using Fabric Manager, follow these steps:
Step 1
Expand a fabric, expand a VSAN and then select Advanced in the Logical Domains pane.
Step 2
Select the RSCN Event tab.
You see the VSAN advanced configuration in the Information pane shown in
Figure 34-6
Double-click the TimeOut value to change the value (in milliseconds) for the selected VSAN.
Step 3
Click Apply Changes to save these changes, or click Undo Changes to cancel any unsaved changes.
Step 4
Default Settings
Table 34-1
Cisco MDS 9000 Family Fabric Manager Configuration Guide
34-8
VSAN Advanced Configuration
lists the default settings for RSCN.
Chapter 34
Managing FLOGI, Name Server, FDMI, and RSCN Databases
OL-17256-03, Cisco MDS NX-OS Release 4.x
Figure
34-6.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents