Configuring NPV
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
On the 91x4 platform, before you downgrade from 3.2(2c) to earlier versions, shut the F port, enable
and disable the FC domain persistency for that VSAN and then up the F port.
To use Fabric Manager and Device Manager to configure NPV, follow these steps:
Launch Device Manager from the core NPV switch to enable NPIV on the core NPV switch. From the
Step 1
Admin drop-down menu, select Feature Control. Select enable for the NPIV feature (see
Figure 21-4
Click Apply.
Step 2
From the Interface drop-down menu, select FC All to configure the NPIV core switch port as an F Port.
Step 3
In the Mode Admin column, select the F port mode and click Apply.
Step 4
Step 5
Launch Device Manager from the NPV device to enable NPV on the NPV device. From the Admin
drop-down menu, select Feature Control. Select enable for the NPV feature and click Apply.
From the Interface drop-down menu, select FC All to configure the external interfaces on the NPV
Step 6
device.
In the Mode Admin column, select the NP port mode and click Apply.
Step 7
From the Interface drop-down menu, select FC All to configure the server interfaces on the NPV device.
Step 8
Step 9
In the Mode Admin column, select F port mode and click Apply.
Step 10
The default Admin status is down. After configuring port modes, you must select up Admin Status to
bring up the links.
Cisco MDS 9000 Family Fabric Manager Configuration Guide
21-8
Enabling NPIV and NPV
Chapter 21
Configuring N Port Virtualization
Figure
OL-17256-03, Cisco MDS NX-OS Release 4.x
21-4).