Configuring Persistent Fc Ids - Cisco AP775A - Nexus Converged Network Switch 5010 Configuration Manual

Fabric manager configuration guide, release 4.x
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

FC IDs
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
FICON uses a different scheme for allocating FC IDs based in the front panel port number. This scheme
Note
takes precedence over FC ID persistence in FICON VSANs.

Configuring Persistent FC IDs

Cisco MDS 9000 Family Fabric Manager Configuration Guide
25-18
Ensure that the required VSAN is an active VSAN—persistent FC IDs can only be configured on
active VSANs.
Verify that the domain part of the FC ID is the same as the runtime domain ID in the required VSAN.
If the software detects a domain mismatch, the command is rejected.
Verify that the port field of the FC ID is 0 (zero) when configuring an area.
Chapter 25
Configuring Domain Parameters
OL-17256-03, Cisco MDS NX-OS Release 4.x