Cisco AP775A - Nexus Converged Network Switch 5010 Configuration Manual page 254

Fabric manager configuration guide, release 4.x
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

Installing Cisco Traffic Analyzer
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Click Interfaces > SPAN in Device Manager to configure SPAN on the required switch ports.
Step 5
Click Interfaces > SPAN in Device Manager to verify that the Fibre Channel port connected to the
Step 6
PAA-2 is configured as an SD port. The port mode of the destination interface must be SD.
Click the Sessions tab in Device Manager to verify the correct destination and source of traffic (ingress).
Step 7
Cisco Traffic Analyzer must not be used with the PAA-2 in Management mode (MNM). Refer to the
Caution
Cisco MDS 9000 Family Port Analyzer Adapter 2 Installation and Configuration Note.
To install Cisco Traffic Analyzer on a Windows workstation, follow these steps:
Open a browser and go to the following website to access the web page where Cisco Traffic Analyzer is
Step 1
available:
http://cisco.com/cgi-bin/tablebuild.pl/mds-fm.
Download ntop-win32.zip and save it on your workstation.
Step 2
Unzip the downloaded file.
Step 3
Note
Step 4
Open a command prompt and change directories to your ntop installation directory.
Type ntop -i or install ntop as a service on Windows by following these steps:
Step 5
Type ntop /i to install ntop as a service.
a.
Choose Start > Programs > Administrative Tools > Services to access the Windows Services
b.
Panel.
Right-click ntop and choose properties. You see the Properties dialog box.
c.
Set the Start Parameters to -i interface number, where interface number is the number of the
d.
interface on your workstation that connects to the PAA-2.
Click Start to start ntop on that interface.
e.
Note
Verify that the Fibre Channel port on the PAA-2 is connected to the SD port on the switch
Step 6
Verify that the Ethernet port on the PAA-2 is connected to the workstation running Cisco Traffic
Step 7
Analyzer.
Click Interfaces > SPAN in Device Manager to configure SPAN on the required switch ports.
Step 8
Click the Sources tab in Device Manager to verify that the Fibre Channel port connected to the PAA-2
Step 9
is configured as an SD port. The port mode of the destination interface must be SD.
Click the Sessions tab in Device Manager to verify the correct destination and source of traffic (ingress).
Step 10
Cisco MDS 9000 Family Fabric Manager Configuration Guide
9-4
You need the WinPcap library file to use Cisco Traffic Analyzer on a Microsoft Windows
system.You can download this file from the following website:
http://winpcap.polito.it/.
Subsequent restarts of the ntop service do not require setting the -i option. unless you are
changing the interface that connects to the PAA-2.
Chapter 9
Cisco Traffic Analyzer
(Figure
OL-17256-03, Cisco MDS NX-OS Release 4.x
9-2).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents