UART2
20-16
Table 20-17. Bank Select Bits [6:5]
BANK 1
BANK 0
0
0
8250A/16450 Compatible Bank (Bank 0)
0
1
General Work Bank (Bank 1)
1
0
General Configuration Bank (Bank 2)
1
1
Baud Rate Generation Configuration Bank (Bank 3)
Table 20-18. Pending Interrupt Status Bits [3:1]
BI2
BI1
BI0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
LH75400/01/10/11 (Preliminary) User's Guide
SELECTED BANK
PENDING INTERRUPT
Not Used
Transmit FIFO Interrupt (lowest priority)
Receive FIFO Interrupt
Receiver Interrupt
Transmitter Interrupt
Timer Interrupt (highest priority)
6/17/03