Timers

15.2.2.20 Timer Interrupts

The timer interrupts are:
• Timer 0 Combined Interrupt — a combined interrupt formed by ORing the two compare,
five capture, and one overflow interrupts in Timer 0.
• Timer 1 Combined Interrupt — a combined interrupt formed by ORing the two compare,
two capture, and one overflow interrupts in Timer 1.
• Timer 2 Combined Interrupt — a combined interrupt formed by ORing the two compare,
two capture, and one overflow interrupts in Timer 2.
Each Timer ORs its individual interrupt to provide a single combined interrupt.
If an individual interrupt is enabled and the corresponding interrupt condition (compare, cap-
ture, or overflow) occurs, a combined interrupt also occurs. Once the interrupt condition occurs,
the combined Interrupt Output signal goes active to '1'. It remains active until all compare, cap-
ture, and overflow interrupts are cleared in the appropriate Status Register or disabled.