Replacement Of Customer I/O Power Supply - ABB IRC5 Product Manual

Robot controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

4 Repair activities, controller IRC5

4.3.4. Replacement of customer I/O power supply

4.3.4. Replacement of customer I/O power supply
General
In the Single Cabinet Controller and Dual Cabinet Controller the customer I/O power supply
DSQC 608 will be replaced by the customer I/O power supply DSQC 609. The replacement
will start from August 2007.
Location
The customer I/O power supply is located as shown in the figure below. For the Dual Cabinet
Controller the customer I/O power supply is located in the Control Module with the same
placement.
xx0700000139
A
B
C
CAUTION!
If there are two or more Customer I/O power supply units mounted in a row and too close to
each other, there will be a heating problem and the units can be damaged.
To avoid damaging the Customer I/O power supply units, the units must be separated with 3
pcs of exterior support.
Required equipment
Equipment
Customer I/O power supply
196
Customer I/O power supply
Power distribution board
System power supply
Spare part no.
3HAC14178-1
Art. no.
Note
DSQC 609
Continues on next page
3HAC021313-001 Revision: K