ABB IRC5 Product Manual page 72

Robot controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

2 Installation and Commissioning, IRC5
2.5.10. The MOTORS ON/MOTORS OFF circuit
Continued
Technical data per chain
GS/AS/SS open "0"
External supply of GS/AS/SS
GS/AS/SS Filter time
Max. potential in relation to the
cabinet earthing and other signal
groups.
Signal class
1) When connecting e.g. a Safety PLC to a safety stop, make sure that the safety check pulses
not exceeds 2,0 ms, otherwise a safety relay must be connected in between. See illustration
below.
xx0800000130
70
IRC5
PLC
Panel board (A21)
Contact X5
X5.11 (AS1+)
X5.12 (24 V)
X5.3 (AS2-)
X5.1 (0 V)
< 5 V
Max. + 35 VDC
Min. - 35 VDC
1)
2,0 ms
300 V
Control signals
Safet y relay
3HAC021313-001 Revision: K
Continues on next page