3HAC021313-001 Revision: K
Action
2. Follow step 2 through 5 in
exchanger fan on page
3. Mark the placement of the heat exchange unit
with a pen before removal.
4. Use a chisel and a hammer to wedge between
the heat exchange unit and cabinet wall in all
four coners of the heat exchanger.
5. Remove the exchanger unit.
6. Apply the adhesive on a cleaned and dry
surface on the new heat exchanger unit.
7. Fit the new heat exchange unit within 20min. It
could be necessary to fixate the unit in position
until the adhesive is hard.
8. Follow the step 1 to 4 in
exchanger fan on page
4 Repair activities, controller IRC5
4.8. Replacement of heat exchange unit and fan
Note/Illustration
Removal of heat
219.
xx0600002677
xx0600002678
Refitting of heat
220.
Continued
A
B
•
A: chisel
•
B: heat exchange unit
•
A: heat exchange unit
•
B: adhesive run
A
B
221