Fault 17: Motor Speed Stall - Cutting Unit 1; Power To The Cutting Reel Motors; Refer To Figure - Toro Greensmaster TriFlex 3300 Manual

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Fault 17: Motor Speed Stall – Cutting Unit 1
InfoCenter Display:
Fault Description
This fault is reported when cutting unit 1 was at zero RPM for more than 3 seconds. Insufficient torque exists
to rotate the reel motor.
Note:
The Greensmaster TriFlex 3320 and 3420 are designed to cut short grass on golf-course greens and
maintained turf on fairways. When using a TriFlex to cut longer grass on a fairway or in the rough, the cutting
unit motors may overheat simply because they are being overworked. Before trying to troubleshoot this fault,
interview the operator about the mowing conditions when the fault occurred. The source of the fault may be as
simple as the machine being used in a manner outside its designed purpose.
Note:
If your machine reports a Fault 13: High Temperature Warning – Reel Motor 1 and a fault 17,
troubleshoot the fault 13 first. A side effect of a fault 13 is reduced reel speed, which causes an increased
chance of a fault 17, Motor Speed Stall – Reel Motor 1.
Circuit Description
All three cutting reel motors and the starter/generator are linked on the 48 V CAN bus circuit.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Check for any mechanical interference.
WARNING
Contact with the cutting reels or other moving parts can result in personal injury.
Keep fingers, hands, and clothing away from the cutting reels or other moving parts.
Never attempt to turn the cutting reels by hand while the engine is running.
1.
Go to
Preparing for Troubleshooting and/or Testing (page 20)
2.
Disconnect the 48 V power to the cutting reel motors. Refer to
V Power to the Cutting Reel Motors (page
3.
Refer to
Figure 24
____FAULT
Returning the Machine to Service (page 21)
to locate cutting unit 1.
#17____
1 STALLED
Clearing Faults from the InfoCenter (page
and follow the steps listed.
Connecting and Disconnecting the 48
18).
44
19).
and follow the steps listed.