Fault 66: Software Version Incompatibility

InfoCenter Display:
Fault Description
This fault is reported when one or more of the machine controllers has software that is incompatible with
the software in the TEC-5001 controller.
Circuit Description
The software in all three cutting units and the S/G must be compatible with the software in the primary TEC
and the InfoCenter.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Use Toro DIAG to reprogram the machine.
Use Toro DIAG to reprogram the machine. If the first attempt to reprogram the machine is unsuccessful, try
reprogramming the machine a second time.
1.
Connect a PC with Toro DIAG software to the machine via a Toro DIAG Cable (Part No. 115-1944). Refer
to
Toro DIAG–Quick Start (page
2.
Use the Toro DIAG software to reprogram the machine in accordance with Toro DIAG User's Guide. The
cutting reel motor is reprogrammed during the reprogramming of the machine.
3.
Disconnect the Toro DIAG cable from the machine.
Pass
If reprogramming the machine was successful, go to
and follow the steps listed.
Fail
If both attempts to reprogram the machine are unsuccessful, contact the Toro Assistance Center
(TAC).
_____FAULT
#66_____
SOFTWARE
INCOMPATIBLE
Clearing Faults from the InfoCenter (page
Returning the Machine to Service (page 21)
22).
172
and follow the steps listed.
Returning the Machine to Service (page 21)
19).