Toro Greensmaster TriFlex 3300 Manual page 97

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

1. Alternator
3.
Unplug main harness connector P02 from the coolant temperature sender.
4.
Inspect harness connector P02 and the temperature sender connector for the following:
damage
corrosion
debris
proper alignment and seating of the pins inside the connectors
Pass
The wiring inspection check passed.
Leave connector P02 unplugged from the temperature sender.
Go to Step 3.
Fail
One or more of the inspection checks failed. Repair or replace the worn or damaged parts. Go to
Returning the Machine to Service (page 21)
Step 3: Test the coolant temperature sender.
1.
Measure the resistance across the pins of the temperature sender following the procedure in Chapter 6 of
the Greensmaster TriFlex 3320/3420 Service Manual.
2.
Wait 10 minutes to allow the engine to cool and then measure the resistance across the pins of the
temperature sender again. As the engine cools, the resistance across the pins of the temperature sender
should increase. The following table shows sample data across a wide range of temperatures.
Temperature
20 °C (68 °F)
30 °C (86 °F)
40 °C (104 °F)
60 °C (140 °F)
95 °C (200 °F)
105 °C (220 °F)
115 °C (240 °F)
Figure 61
2. Temperature sender
and follow the steps listed.
Temperature Sender Resistance
97
11.4 to 13.6 k ohms
7.4 to 8.75 k ohms
4.9 to 5.75 k ohms
2.3 to 2.6 k ohms
740 to 830 ohms
560 to 630 ohms
420 to 470 ohms
g238438