Toro Greensmaster TriFlex 3300 Manual page 98

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Pass
As the engine cooled, the resistance through the temperature sender increased. Go to Step 4.
Plug connector P02 in to the temperature sender.
Go to Step 4.
Fail
As the engine cooled, the resistance through the temperature sender did not increase. Replace
the temperature sender according to the procedure outlined in the Component Testing section in
Chapter 6 of the Greensmaster TriFlex 3320/3420 Service Manual. Go to
Service (page 21)
Step 4: Test the temperature sensor wiring.
This Step tests the temperature sender wiring from the TEC-5001 through the temperature sender.
1.
Remove the right side cover
1. Right side cover
2.
Slide the operator seat assembly all the way toward the rear of the machine. Then tilt the seat itself forward.
3.
Locate the TEC-5001 controller
and follow the steps listed.
(Figure
62).
Figure 62
(Figure
63).
98
Returning the Machine to
g237042

Advertisement

Table of Contents