Toro Greensmaster TriFlex 3300 Manual page 302

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

1. E-reels harness connector
P21
6.
Connect the 48 V power. Refer to
Motors (page
18).
7.
Operate the machine.
Pass
The fault did not repeat. Go to Step 3 and continue there.
Fail
If the fault repeats, contact the Toro Technical Assistance Center for additional guidance.
Step 3: Individually connect each cutting reel motor.
The purpose of Step 3 is to identify which reel motor is shorted.
1.
Disconnect 48 V power from the cutting units by separating the cutting unit power connectors. This
prevents unexpected operation of cutting units. Refer to
to the Cutting Reel Motors (page
2.
Locate and connect the 2 cutting reel motor connectors to the e-reels harness connectors P17 and P18 for
cutting unit 1.
(Figure
3.
Connect the 48 V power to the cutting reel motors. Refer to
to the Cutting Reel Motors (page
4.
Operate the machine.
Pass
The fault did not return. Go to substep 5 and continue there.
Fail
The fault returned. The reel motor in cutting unit 1 has failed. Go to Step 4 and follow the
steps listed.
5.
Disconnect 48 V power from the cutting units by separating the cutting unit power connectors. This
prevents unexpected operation of cutting units. Refer to
to the Cutting Reel Motors (page
6.
Locate and connect the 2 cutting reel motor connectors to the e-reels harness connectors P19 and P20 for
cutting unit 2.
(Figure
7.
Connect the 48 V power to the cutting reel motors. Refer to
to the Cutting Reel Motors (page
8.
Operate the machine.
g236001
Figure 169
2. Right front tire
Connecting and Disconnecting the 48 V Power to the Cutting Reel
18).
167).
18).
18).
168).
18).
1. E-reels harness connector
P22
Connecting and Disconnecting the 48 V Power
Connecting and Disconnecting the 48 V Power
Connecting and Disconnecting the 48 V Power
Connecting and Disconnecting the 48 V Power
302
g236002
Figure 170
2. Right front tire

Advertisement