Fault 64: Main Power Relay Failure

InfoCenter Display:
Fault Description
This fault is reported when the TEC has sensed a main power relay failure.
Circuit Description
The main power relay provides electrical current to the fuse blocks when energized by the ignition switch
in the R
or S
position.
UN
TART
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Verify power at the InfoCenter
1.
Turn the key switch to the O
2.
Verify that the InfoCenter lights up.
Pass
The InfoCenter lit up. Go to Step 3.
Fail
The InfoCenter did not light up. Go to Step 4.
_____FAULT
MAIN POWER RELAY
Returning the Machine to Service (page 21)
position.
N
169
#64_____
Clearing Faults from the InfoCenter (page
19).
and follow the steps listed.