The resistance tests passed, but the voltage readings in Step 8 are still bad.
Note:
Do not go to Step 10 until after the voltage readings in Step 8 are good, and the fault
is still reporting.
Fail
One or more of the power and ground wiring tests failed. Repair or replace the worn or damaged
parts. Go to
Step 10: Swap cutting reel motors between cutting units.
All of the cutting reel motors are identical.
1.
Locate cutting reel motor 2.
1. Cutting unit 1 (center), which includes reel motor 1
2. Cutting unit 2 (left), which includes reel motor 2
2.
Verify that the cutting units are disconnected from the 48 V power system (the cutting unit power
connectors are separated). This prevents unexpected operation of cutting units. Refer to
Disconnecting the 48 V Power to the Cutting Reel Motors (page
Pin
Connector
P19
1
P09
4
Returning the Machine to Service (page 21)
Wire
Expected
Color
Reading
White (W)
30k to 32k
Black
ohms
(BK)
(48 V
Ground)
and follow the steps listed.