Fault 84: Electronic Reel Motor Enable –
Current High
InfoCenter Display:
Fault Description
This fault is reported when the 48 V logic relay output current is too high.
Circuit Description
After a request is sent to the primary TEC, the 48 V logic relay sends an output signal to the cutting unit to
begin work at a predetermined speed.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
_____FAULT
#84_____
eREEL ENABLE -
OVER
Clearing Faults from the InfoCenter (page
Returning the Machine to Service (page 21)
206
19).
and follow the steps listed.