debris
proper alignment and seating of the pins inside the connectors
5.
Inspect the 2 cutting reel motor cable connectors for proper wire color per pin, as shown in the following 2
tables.
Leave the 2 cutting reel motor cable connectors unplugged from the e-reels harness connectors
Leave the 48 V power disconnected from the cutting units from the system. This prevents
unexpected operation of cutting units. Refer to
to the Cutting Reel Motors (page
Go to Step 4.
Step 3: Test the CAN bus wiring in e-reels harness connector P17.
Use a multimeter to test the resistance between the following pairs of locations:
1
E-reels
2
E-reels
1
E-reels
2
1
E-reels
2
Cutting Reel Motor, 4-Pin Connector
Pin Number
1
2
3
4
Cutting Reel Motor, 2-Pin Connector
Pin Number
1
2
P17
3
Yellow (Y)
P17
4
P17
3
Yellow (Y)
Chassis ground
P17
4
Chassis ground
Wire Color
White (W)
Yellow (Y)
18).
and follow the steps listed.
Wire
Color
54 to 66
Green
ohms
(GN)
Open
(infinite)
Green
Open
(GN)
(infinite)
67