Toro Greensmaster TriFlex 3300 Manual page 249

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Location
Harness
1
Main
2
Main
5.
If one or more of the power and ground wiring tests failed, repair or replace any worn or damaged parts.
Go to
Returning the Machine to Service (page 21)
Pin
Connector
P18
2
Ground)
P20
2
Ground)
Wire
Expected
Color
Reading
Black
(BK)
(48 V
Less than
2 ohms
Black
(BK)
(48 V
and follow the steps listed.