Returning the Machine to Service
Ensure optimum performance and continued safety by performing all steps in the following procedure after all
diagnostic, maintenance, and/or repair activities are complete:
1.
Remove all diagnostic equipment and tools that are attached to the machine for troubleshooting or repair.
2.
Fully reassemble the machine. This includes all guards, covers, cable ties, and parts loosened or removed.
3.
If you unplugged the 48 V battery connector, plug it back in. Refer to
48 V Power to the Cutting Reel Motors (page
4.
Ensure that all nuts, bolts, screws, and belts are properly tightened.
5.
Start the engine.
6.
Clear all faults from the InfoCenter. Refer to
Note:
If you replaced a cutting reel motor, the motor/generator controller, InfoCenter, or the TEC-5001,
you may receive a Software Version Incompatibility fault (i.e., fault 66, 141, 142, 143, 144, 145) for the
replacement component. If you do receive a fault, follow the diagnostic path in this manual for that
specific fault.
7.
Run the machine and verify that all systems function safely and correctly.
8.
If any faults are reported while running the machine, follow the procedures outlined in this manual
to correct them.
Note:
If you receive the same fault that you were troubleshooting, go back to the troubleshooting step on
which you last worked. Review all previous diagnostic steps to determine a diagnostic plan. It may be
necessary to restart troubleshooting from the beginning.
18).
Clearing Faults from the InfoCenter (page
21
Connecting and Disconnecting the
19).