Toro Greensmaster TriFlex 3300 Manual page 139

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Location
Harness
1
Main
2
Main
CAUTION
Overtightening the harness connector retaining fastener will damage the primary TEC
controller.
After you plug connector P01 back into the TEC, torque the retaining fastener for P01 to 25–28
in-lbs.
Pass
The wiring passed the continuity test. Begin the diagnostic process again.
Fail
The wiring did not pass the continuity test. Repair or replace the damaged wiring.
Machine to Service (page 21)
Pin
Connector
P57
A
P01
39
and follow the steps listed.
Wire
Expected
Color
Reading
Violet
(VIO)
Less than
2 ohms
Violet
(VIO)
139
Connector Graphic