6.
Use a multimeter to test the resistance between the two pins in the connector on the solenoid. The
reading should be between 8 and 10 ohms.
Pass
The resistance measurement was good.
Plug connector P09 back in to the S1 solenoid.
Do not reinstall the right-hand cover.
Go to Step 3.
Fail
The resistance measurement was not good. Repair or replace worn or damaged parts as
required. Go to
Step 3: Test the wiring for solenoid S1.
1.
Slide the operator seat assembly all the way toward the rear of the machine. Then tilt the seat itself forward.
2.
Locate the primary TEC controller.
1. Right front tire
2. Operator seat
3.
Remove the four mounting bolts that secure the primary TEC controller
4.
Lift the TEC up and out of its mounted location
5.
Fully loosen the socket-head screw that secures main harness connector P01 to the primary TEC
99) and then unplug the connector.
Returning the Machine to Service (page 21)
Figure 98
(Figure
3. Primary TEC controller
4. Mounting bolts (2 of 4 are shown)