Toro Greensmaster TriFlex 3300 Manual page 328

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Fault 146: CAN Bus Fault – InfoCenter
InfoCenter Display:
Fault Description
This fault is reported when the primary TEC-5001 controller loses or never established communication with the
InfoCenter.
Circuit Description
The InfoCenter is connected to the 12 V CAN bus, along with the primary TEC-5001.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Determine if the InfoCenter is functioning properly.
1.
Start the engine and observe the InfoCenter readouts.
2.
Scroll through the screens to verify that the InfoCenter is receiving data.
Pass
The InfoCenter is operating normally. Go to Step 3.
Fail
The InfoCenter is not functioning. Go to Step 5.
Step 3: Prepare to test the InfoCenter wiring and/or replace the
InfoCenter.
To test the InfoCenter wiring or replace the InfoCenter, remove the console cover as follows:
1.
Remove the eight screws that secure the console cover to the underside of the console
This allows access inside the console.
_____FAULT
#146____
Clearing Faults from the InfoCenter (page
Returning the Machine to Service (page 21)
328
19).
and follow the steps listed.
(Figure
182).