Toro Greensmaster TriFlex 3300 Manual page 91

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

1. Left-hand side cover
2. Step
2.
Unplug connector P20 from the motor harness connector.
3.
Use a multimeter to test the resistance between the following pairs of locations:
Location
Harness
1
Main
2
Main
1
Main
2
Main
Connector
Pin
P09
3
Red (R)
P20
1
Red (R)
P09
4
Ground)
P20
2
Ground)
Figure 59
3. Motor harness connector
4. E-reels harness connector P20
Wire
Expected
Color
Reading
Less than
2 ohms
Black
(BK)
(48 V
Less than
2 ohms
Black
(BK)
(48 V
91
Connector Graphic
g239648