Toro Greensmaster TriFlex 3300 Manual page 151

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Pass
The internal generator connections and cables do not have evidence of damage or corrosion. Go
to Step 4.
Fail
The generator internal connections and/or wires have evidence of damage and/or corrosion. Repair
or replace all damaged generator internal connections and/or wires. Go to
Service (page 21)
Step 4: Install a replacement controller onto the starter/generator.
1.
Remove the generator from the machine. Refer to Generator Assembly Service in Chapter 6 of the
Greensmaster TriFlex 3320/3420 Service Manual and follow the generator assembly removal procedure.
2.
Remove and replace the starter/generator controller.
Step 5: Install the starter/generator assembly.
Install the starter/generator into the machine. Refer to Generator Assembly Service in Chapter 6 of the
Greensmaster TriFlex 3320/3420 Service Manual and follow the generator assembly installation procedure.
Step 6: Use Toro DIAG to program the starter/generator.
1.
Connect a PC with Toro DIAG software to the machine via a Toro DIAG Cable (Part No. 115-1944). Refer
to Toro DIAG - Quick Start
2.
Use the Toro DIAG software to reprogram the machine in accordance with Toro DIAG User's Guide. The
replacement starter/generator is programmed during the reprogramming of the machine.
3.
Disconnect the Toro DIAG cable from the machine.
4.
Go to
Returning the Machine to Service (page 21)
Step 7: Test the machine function.
With the engine running, test the function of the machine and ensure that the fault no longer reports.
Pass
The fault no longer exists.
Fail
The fault still reports. Repeat the diagnostic process.
and follow the steps listed.
Toro DIAG USB/CAN Cable (page
10).
and follow the steps listed.
151
Returning the Machine to

Advertisement

Table of Contents
loading

Table of Contents