3.
Use a multimeter to measure the resistance between pin A and pin B of each terminator
The measurements should be 108 to 132 ohms.
Pass
The resistance measurements were good. Go to Step 9.
Fail
One or more of the resistance measurements was not good.
A.
Replace the terminator(s) that failed the test.
B.
Go to
Step 9: Test the CAN Bus terminator resistors on the e-reels harness.
1.
Locate the two terminators and unplug them from the harness
1. CAN bus terminator in e-reels harness connector P13
2. CAN diag port (e-reels harness connector P23 in protective
cap)
2.
Use a multimeter to measure the resistance between pin A and pin B of each terminator
The measurements should be 108 to 132 ohms.
Returning the Machine to Service (page 21)
Figure 34
and follow the steps listed.
(Figure
Figure 35
3. CAN bus terminator in e-reels harness connector P14
Figure 36
62
(Figure
35).
(Figure
34).
g228409
g246028
36).
g228409