Fault 112: Internal Regulator Low Voltage –
Reel Motor 1
Note:
When any individual cutting reel motor is shut off due to a fault, the TEC-5001 shuts off the other
cutting reel motors.
Note:
If multiple machine faults are reported within a few seconds, troubleshooting should begin with the
first cutting reel motor to report a fault.
InfoCenter Display:
Fault Description
Insufficient voltage was detected at the internal voltage regulator for cutting reel motor 1. This fault can occur
if the cutting reel motor unexpectedly loses power. For example, if the cutting reel motor connector is pulled
apart when powered, this fault is reported.
Circuit Description
Each cutting reel motor has an internal voltage regulator.
Note:
The internal voltage regulator is not a serviceable part.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Inspect the wiring for cutting reel motor 1.
1.
Locate the 2 cutting reel motor connectors and the e-reels harness connectors P17 and P18.
_____FAULT
#112____
1 - INTERNAL
UNDER V
Clearing Faults from the InfoCenter (page
Returning the Machine to Service (page 21)
268
19).
and follow the steps listed.