Toro Greensmaster TriFlex 3300 Manual page 30

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

1. 48V Logic relay
2. Main contactor
5.
Disconnect J07 from the main contactor and then use a multimeter to test the resistance between the
following pair of locations:
Location
Harness
1
E-reels
2
E-reels
6.
Locate the 48V Logic relay, near the main contactor
7.
Locate connector J02 on the main contactor
8.
Remove connector P07 from the 48V Logic relay and then use a multimeter to test the resistance between
the following pair of locations:
Location
Harness
1
E-reels
2
E-reels
9.
Repair or replace the worn or damaged parts. Go to
follow the steps listed.
Figure 18
Connector
Pin
J07
N/A
P09
3
(Figure
Connector
Pin
J02
N/A
White (W)
P07
4
White (W)
3. Connector J07
4. Connector J02
Wire
Expected
Color
Reading
Red (R)
less than
2 ohms
Red (R)
(Figure
18).
18).
Wire
Expected
Color
Reading
less than
2 ohms
Returning the Machine to Service (page 21)
30
Connector Graphic
Connector Graphic
and
g234997

Advertisement

Table of Contents
loading

Table of Contents