Suzuki Ignis Service Manual page 353

Rg413
Table of Contents

Advertisement

INSPECTION
Step
1
Is G sensor installed floor securely?
2
1) Ignition switch OFF.
2) Remove G sensor with bracket.
3) Check for proper connection to G sensor.
4) If OK then check G sensor referring to
INSPECTION of "G SENSOR".
Is it in good condition?
3
1) Disconnect connectors from ABS hydraulic
unit/control module assembly and G sensor.
2) Check for proper connection to ABS control
module at terminals "E19-11" and "E19-13".
3) If OK, then turn ignition switch ON and mea-
sure voltage between "GRN/ORN" terminal
of sensor connector and body ground.
It is 10 – 14 V?
4
Measure voltage between "ORN" terminal of
sensor connector and body ground.
Is it 0 V?
5
1) Ignition switch OFF.
2) Check that "ORN" circuit is free from open
or short to ground and "BLK/ORN" circuit.
Is it in good condition?
Action
ANTILOCK BRAKE SYSTEM (ABS) 5E-23
Yes
Go to Step 2.
Go to Step 3.
Go to Step 4.
Go to Step 5.
"BLK/ORN" circuit open.
If circuit is OK, substitute
a known-good ABS
hydraulic unit/control
module assembly.
No
Tighten sensor or bracket
screw securely. If not,
using new screw.
Replace G sensor.
"GRN/ORN" circuit open.
"ORN" circuit shorted to
power circuit.
"ORN" circuit open or
shorted to ground or
"BLK/ORN" circuit.

Advertisement

Table of Contents
loading

Table of Contents