Water Pump - Suzuki Ignis Service Manual

Rg413
Table of Contents

Advertisement

6B-16 ENGINE COOLING
4
3
1
3
2
INSTALLATION
2
1
WATER PUMP BELT TENSION INSPECTION AND
ADJUSTMENT
For this inspection or adjustment, refer to "WATER PUMP GEN-
ERATOR DRIVE BELT TENSION INSPECTION AND ADJUST-
MENT".

WATER PUMP

REMOVAL
4
1) Install belt (1) to water pump pulley (2), crankshaft pulley (3)
and generator pulley (4).
When servicing car equipped with A/C, install compressor
drive belt, too.
2) Adjust belt tension by referring to "WATER PUMP/GENERA-
TOR DRIVE BELT TENSION INSPECTION AND ADJUST-
MENT" in this section.
For adjustment of compressor drive belt tension, refer to
COMPRESSOR DRIVE BELT in Section 1B.
3) Tighten water pump belt adjusting bolt and pivot bolt to spec-
ified torque.
Tightening torque
Generator adjusting bolt (a) : 23 N·m (2.3 kg-m, 17.0 lb-ft)
Generator pivot bolt (b) : 50 N·m (5.0 kg-m, 36.0 lb-ft)
4) Connect negative cable at battery.
1) Disconnect negative cable at battery.
2) Drain coolant. Refer to "COOLING SYSTEM DRAINING".
3) Remove A/C compressor belt (4) by referring to "COM-
PRESSOR DRIVE BELT" in Section 1B. (if equipped).
4) Loosen water pump/generator drive belt adjusting bolt (1)
and generator pivot bolt (2). Then remove water pump/gen-
erator drive belt (3) and water pump pulley.
Refer to "WATER PUMP BELT" in this section.

Advertisement

Table of Contents
loading