(2) Intelligent function module and I/O module
PLC CPU and motion controller CPU
RCPU
QCPU
Motion controller CPU (Q series)
C Controller module (Q Series)
QSCPU
LCPU
To monitor modules other than the above ones, use the BM monitor.
■2. Connection type
(○: Available, ×: Unavailable)
Function
Name
Description
Monitors buffer
memory of
Intelligent
intelligent
module
function module
monitor
and signal
statuses of I/O
modules
*1
For the MELSECNET/10 connection, use a QCPU and network module (QJ71LP21, QJ71LP21-25, QJ71LP21S-25, and
QJ71BR11) with the function version B or later.
*2
The QSCPU does not support the connection type.
*3
The LCPU does not support the connection type.
*4
When the GOT is connected to LCPU, use L6ADP-R2.
*5
Intelligent module monitor cannot be used when using CC-Link IE field network Ethernet adapter.
*6
Indicates the CC-Link IE controller network connection.
*7
Indicates CC-Link IE field network connection.
*8
Indicates CC-Link connection (Intelligent device station).
*9
Indicates CC-Link connection (via G4).
*10
The RCPU does not support the connection type.
■3. Required system application (extended function)
For the system application (extended function) required, refer to the following.
1.2 System Applications (Extended Functions) Required for Each Function
(1) System application (extended function)
Write the package data that contains the system application (extended function) for the intelligent module monitor to
the GOT.
For the communication method with the GOT, refer to the following.
GT Designer3 (GOT2000) Screen Design Manual
(2) System application (extended function) size
To install a system application (extended function) to the GOT, enough space in the user area is required.
For information on how to check the available space of the user area and each data size, refer to the following.
GT Designer3 (GOT2000) Screen Design Manual
■4. Applicable hardware
Hardware
USB mouse
Intelligent function module
R60AD4, R60ADV8, R60ADI8, R60DA4, R60DAV8,
R60DAI8, RD62P2, RD62P2E, RD62D2, RD75P2,
RD75P4, RD75D2, RD75D4, RD77MS2, RD77MS4,
RD77MS8, RD77MS16, RD77GF4, RD77GF8,
RD77GF16
Q62DA, Q64AD, Q64DA, Q68ADV, Q68ADI, QD62,
QD62E, QD62D, QD65PD2, QD73A1, QD75P1,
QD75P2, QD75P4, QD75D1, QD75D2, QD75D4,
QD75MH1, QD75MH2, QD75MH4, QD75M1,
QD75M2, QD75M4, QD77GF4, QD77GF8,
QD77GF16, QD77MS2, QD77MS4, QD77MS16
L60AD4, L60DA4, LD62, LD62D, LD75D1, LD75D2,
LD75D4, LD75P1, LD75P2, LD75P4, LD77MH4,
LD77MH16, LD77MS2, LD77MS4, LD77MS16
Connection type between GOT and PLC CPU
Bus
Direct CPU
Serial
connection
connection
communication
*2*3*10
*2*4*10
connection
RX10, RX40C7, RX41C4, RX42C4, RY40NT5P,
RY41NT2P, RY42NT2P, RY10R2,
RH42C4NT2P
MELSEC-Q series input modules,
MELSEC-Q series output modules,
QH42P, QX48Y57, QX41Y41P
LX40C6, LX41C4, LX42C4, LY10R2, LY41NT1P,
LY42NT1P,
LH42C4NT1P, LH42C4PT1P
MELSECNET/H
Ethernet
*3*10
connection
,
connection
MELSECNET/10
*2
*5
*3*10
connection
*1
8.2 Specifications
I/O module
CC-Link IE
CC-Link
controller
connection
*3*6
connection
,
CC-Link IE field
*2*8
*2*9*10
ID
G4
*7
connection
8 - 3
8