Specifications; System Configuration - Mitsubishi Electric GOT2000 Series User Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

10.2 Specifications

10.2.1

System configuration

This section describes the system configuration for the backup/restoration function.
For connection type settings and precautions regarding the communication unit/cable and connection type, refer to the
following.
GOT2000 Series Connection Manual (Mitsubishi Products) For GT Works3 Version1
■1. Target controller
Controller
RCPU
Motion controller CPU (MELSEC iQ-R Series)
QCPU (Q mode)
Motion controller CPU (Q series)
LCPU
*5
FXCPU
CNC C80
CNC C70
MELSERVO-J4 series
FREQROL-A series
*9
Robot controller
*1
When executing the network batch backup/restoration, use controllers compatible with the Ethernet connection.
For the controllers compatible with Ethernet connection, refer to the following.
*2
Use a PLC CPU with the function version of B or later.
*3
Use the following production number motion controller CPU when using the Q172CPU or Q173CPU.
• For bus connection and direct CPU connection
Q172CPU: Production number K******* or later
Q173CPU: Production number J******* or later
• For connections other than bus connection and direct CPU connection
Q172CPU: Production number N******* or later
Q173CPU: Production number M******* or later
*4
The operation system software of SV13 and SV22 are available only.
Use a motion controller CPU with the following OS installed when using the Q172CPU, Q173CPU, Q172CPUN, or Q173CPUN.
• SW6RN-SV13Q□: 00H or later (00E or later for using the Q172CPU or Q173CPU with the bus connection or direct CPU
connection)
• SW6RN-SV22Q□: 00H or later (00E or later for using the Q172CPU or Q173CPU with the bus connection or direct CPU
connection)
*5
To restore the backup data containing a special parameter, use the following version of CPU.
• FX3U(C) version: 3.10 or later
• FX3G(C) version: 2.00 or later
*6
This controller is supported only when it is equipped with an FR-A8NCE.
*7
FR-A800-GF does not require an FR-A8NCE because the FR-A800-GF has a built-in communication board for the CC-Link IE
Field Network.
*8
FREQROL-A800-R2R is not supported.
*9
For using CRnQ-700 or CRnD-700, use robot controllers with the following versions or later.
*1
R04CPU, R08CPU, R16CPU, R32CPU, R120CPU
R16MTCPU, R32MTCPU
*2
Q00JCPU, Q00CPU, Q01CPU
Basic model
High Performance
Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU,
*2
Q02PHCPU, Q06PHCPU, Q12PHCPU, Q25PHCPU
model
Q00UJCPU, Q00UCPU, Q01UCPU, Q02UCPU, Q03UDCPU, Q04UDHCPU, Q06UDHCPU,
Q10UDHCPU, Q13UDHCPU, Q20UDHCPU, Q26UDHCPU,
Universal model
Q03UDECPU, Q04UDEHCPU, Q06UDEHCPU, Q10UDEHCPU, Q13UDEHCPU,
Q20UDEHCPU, Q26UDEHCPU, Q50UDEHCPU, Q100UDEHCPU,
Q03UDVCPU, Q04UDVCPU, Q06UDVCPU, Q13UDVCPU, Q26UDVCPU
Q172CPU, Q173CPU, Q172HCPU, Q173HCPU,
*3*4
Q172DCPU, Q172DCPU-S1, Q173DCPU, Q173DCPU-S1, Q172DSCPU, Q173DSCPU,
Q170MCPU, Q170MCPU-S1, Q170MSCPU, Q170MSCPU-S1
L02CPU, L06CPU, L26CPU, L26CPU-BT, L26CPU-PBT, L02CPU-P, L02SCPU
FX0, FX0S, FX0N, FX1, FX2, FX2C, FX1S, FX1N, FX1NC, FX2N, FX2NC, FX3U, FX3UC,
FX3G
R16NCCPU
Q173NCCPU
MR-J4-GF
FREQROL-A800 series
CRnQ-700, CR750-Q, CR751-Q,
CRnD-700, CR750-D, CR751-D
GOT2000 Series Connection Manual (Mitsubishi Products) For GT Works3 Version1
Robot controller
CRnQ-700
CRnD-700
Model
*6*7
*6*8
, FREQROL-A800 Plus series
Version
N8 or later
P8 or later
10.2 Specifications
10
10 - 3

Advertisement

Table of Contents
loading