17.4 Operation Procedures
This section describes the display data of the CNC monitor screen and the functions of the keys displayed on the screen.
1) [MONITOR] key
Switches the monitor screen to the position display monitor screen.
2) [DIAGN IN/OUT] key
Switches the monitor screen to the alarm diagnosis monitor screen.
3) [TOOL PARAM] key
Switches the monitor screen to the tool compensation parameter monitor screen.
4) [EDIT MDI] key
Switches the monitor screen to the program monitor screen.
5) [F0] key
Switches the monitor screen to the APLC release screen.
When the monitoring target CNC does not have the APLC release function, the screen becomes blank
(Nothing is displayed in the black screen.).
(When the screen is blank, switch the screen to the one for other functions with the keys of the function
switching section.)
6) [Ch:] key
Displays the communication setting window.
7) [CNC CHG] key
• For bus connection
The key does not function. (Specify the monitoring target in the communication setting window.)
• For Ethernet connection
This key switches CNCs for monitoring when multiple CNCs are connected.
The target CNCs are switched in the order set in the Ethernet setting of GT Designer3.
• For MELSECNET/10 connection
The key does not function because the monitoring target is the control station only (switching not required).
8) [RET] key
Exits the CNC monitor and returns to the monitor screen or the utility of the GOT.