15.4.10 Parameter setting

Sets FX PLC parameters.
■1. Parameters that can be changed and change targets
(1) Parameters that can be changed
The parameters that can be changed with the MELSEC-FX list editor and the target FX PLCs are as follows.
(○: Can be set/changed ×: Cannot be set/changed)
Item
Memory space setting
File register space setting
Latch range setting
RUN terminal setting
Initialization of
parameters
*1
When connecting an FX0(S), set "0".
Setting other than "0" causes a parameter error.
*2
When the parameters are initialized, the display on the MELSEC-FX list editor is different from the FX PLC default values, but do
not change the latch range. Changing the latch range causes an error.
(2) Change targets
When a memory cassette is mounted, the parameters in the memory cassette are targeted for changes.
■2. Operation
*1
Stop the FX PLC
*1
When checking parameters (not changing), it is not necessary to stop the PLC.
FX0(S)
FX1
FX2(C)
/FX0N
×
*1
×
*2
×
×
×
×
OP
[Parameter setting]
*1
Stop the FX PLC
OP
Select [Parameter setting] with
GO
Target CPU
FX1S
FX1N(C)
FX2N(C)
×
×
*2
*2
×
×
GO
or
15.4 Operation Procedures
FX3S
FX3G(C)
FX3U(C)
×
×
.
15 - 23