Specifications; System Configuration - Mitsubishi Electric GOT2000 Series User Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

12.2 Specifications

12.2.1

System configuration

This section describes the system configuration of the log viewer.
■1. Target controller
High Speed Data Logger Module
BOX Data Logger
PLC CPU
CNC C80
CNC C70
*1
*2
■2. Connection type
(1) When using the standard Ethernet interface or the extended Ethernet interface
Controller
Model
Connection type
*3
QD81DL96
*5
NZ2DL
*6
RCPU
*6
QnUDVCPU
*6
LCPU
*7
R16NCCPU
*8
Q173NCCPU-S01
*1
*2
*3
12 - 2
12.2 Specifications
Type
RCPU
*1
QCPU
*1
LCPU
The PLC CPU must be connected by using the built-in Ethernet port.
The PLC CPU must be connected by using port CPU P1.
High Speed Data
Logger Module/
BOX Data Logger/
PLC CPU/
CNC C80/CNC C70
Connection cable
• 100BASE-TX
Shielded twisted pair cable
(STP) or unshielded twisted
pair cable (UTP) of category
Ethernet
5 or higher
connection
• 10BASE-T
Shielded twisted pair cable
(STP) or unshielded twisted
pair cable (UTP) of category
3 or higher
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
A straight cable is available.
When the GOT is directly connected to a controller via an Ethernet cable, a cross cable is applicable.
However, the GOT does not support the direct connection for the controller. Set the IP address on the controller side.
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
QD81DL96
NZ2DL
*1
*1
R04CPU
, R08CPU
, R16CPU
*2
*2
R04ENCPU
, R08ENCPU
Q03UDVCPU, Q04UDVCPU, Q06UDVCPU, Q13UDVCPU, Q26UDVCPU,
Q04UDPVCPU, Q06UDPVCPU, Q13UDPVCPU, Q26UDPVCPU
L02CPU, L02CPU-P,
L06CPU, L06CPU-P,
L26CPU, L26CPU-P, L26CPU-BT, L26CPU-PBT
R16NCCPU
Q173NCCPU-S01
Connection cable
Maximum
segment
*1*2
length
100m
Model
*1
*1
, R32CPU
, R120CPU
*2
, R16ENCPU
, R32ENCPU
GOT
GOT
Option device
*3
- (Built into
GOT)
GT25-
J71E71-100
*1
,
*2
*2
, R120ENCPU
Number of
connectable
Model
equipment
GT27
16 GOTs
GT25

Advertisement

Table of Contents
loading

Table of Contents