Error Messages and Corrective Action

This section describes the error messages that may be displayed during Q motion monitor operation and their corrective
action.
Error message
No. PLC Communications
This PLC type is not supported
Controller's OS type is different
It is not a version for GOT
Monitor data not found
Unused axis selected
It is not possible to select
Incorrect setting range
Unmatched password
Communication channel setup
error
Unsupport amp. selected
7 - 30
7.5 Error Messages and Corrective Action
Error definition
Communication cannot be established with the
PLC CPU of the monitor target.
A motion controller CPU that cannot be
monitored was selected on the System
Configuration screen.
The motion controller OS installed in the motion
controller CPU (Q172CPU, Q173CPU) of the
monitor target is other than SV13 or SV22.
The version of the motion controller OS installed
in the motion controller CPU of the monitor
target is not compatible with the Q motion
monitor.
The monitor data was not installed or was
deleted.
The axis number selected has not been set.
During servo parameter setting, an item that
cannot be set has been selected.
A value that is outside the setting range has
been set.
The entered password is invalid.
A communication driver that is compatible with
the Q motion monitor is not installed.
The number of the axis, which is set to a servo
amplifier having no settable parameter, has
been selected.
POINT
POINT
POINT
How to clear a displayed error message
For the error that occurs during the communication with a controller (such as a communication
error), the error message does not disappear even after the cause of the error has been
removed.
To clear the error message, restart the GOT.
Corrective action
• Check the status of the connection between the controller and the
GOT (disconnected or cut cables).
• Check if an error has occurred in the controller.
Select a motion controller CPU that can be monitored on the System
Configuration screen.
7.2.1 ■1. Target controller
Install SV13 or SV22 in the motion controller CPU (Q172CPU,
Q173CPU) of the monitor target as the motion controller OS.
Install a motion controller OS that is compatible with the Q motion
monitor in the motion controller.
7.2.1 ■1. Target controller
Download the monitor data of the motion monitor.
• Select the axis number that has been set.
• Set the axis using the relevant software.
Select an item that can be set.
Set the value within the setting range.
Input the correct password.
Install a compatible communication driver.
Select the number of the axis, which is set to a servo amplifier having
the settable parameter.