4.8.2

Factor search

The contact point that affected the set device status (ON/OFF) is searched backwards in ladder blocks.
Step 1.
Touch the [Find] → [Factor] menu from the Ladder monitor screen to display the factor search window.
Step 2.
Set a device to be searched, and touch the [Enter] key
• Displayed screen
(For alphabet input)
No.
Item
1)
Device input area
2)
Keys
• Key functions
Key
[X]
[AC]
[Del]
[0-9]
[A-Z]
[Enter]
The following shows the target instructions and coils for Factor search.
Instruction, coil
Instruction
Coil
4 - 50
4.8 Find/Replace Operation
Set a device to be searched.
Bit device words cannot be specified.
Also, by selecting a device on the Ladder monitor screen, the device can be input.
Keys for operations in Factor search window.
Closes the Factor search window.
Deletes all the input values and characters.
Deletes an input value or character.
Switches the key type to the value.
Switches the key type to the alphabet.
By touching the key, the Factor search window is closed and the Ladder registration monitor window is
displayed. The search starts from the last step.
If the device is selected on the Ladder monitor screen, the search starts from the selected device.
When the search is executed, ladder blocks registered in the Ladder registration monitor window are
deleted.
LD, LDI, AND, ANI, OR, ORI
OUT, OUTH
1)
2)
(For numerical input)
Description
Function
Target of the search operation
1)
2)