15.4.2

Selection and operation of modes

The MELSEC-FX list editor has four modes: READ, WRITE, INSERT, and DELETE.
Select an appropriate mode for the intended operation.
For more information on the mode to select, refer to the function operations from subsection 5.4.3 onward.
■1. How to change modes
Touch the [MODE] button.
Each time you touch this button, the mode changes.
■2. In the case the mode cannot be changed
In the following cases, only READ mode is allowed.
If you try to change to other than READ mode, an error message is displayed.
To change to other than READ mode, take the action below.
Error Message
PLC is running
Can not write.
15.4.3

Sequence program display

Sequence programs are read from the FX PLC to the GOT and displayed.
There are two displaying methods: specifying the step number, and scrolling one screen at a time.
■1. Display using cursor keys
(1) Operation
Scroll with
or
(2) Example
Scroll one line upward or downward.
Touch the [MODE] button.
Description
The FX PLC is in the RUN status.
The protect switch of the EEPROM memory
cassette is on.
The EPROM memory cassette is enabled.
.
128
MPP
129
DIV
Scrolling one line upward
128
MPP
129
DIV
23
D56
K200
The current mode is displayed.
Stop the FX PLC.
Switch off the protect switch of the EEPROM
memory cassette.
Set a memory other than EPROM as the memory
to write to.
23
D56
K200
Scrolling one line downward
128
MPP
129
DIV
D56
K200
15.4 Operation Procedures
Corrective action
23
15 - 11