Cisco CTS-3010 Administration Manual page 277

Administration guide
Hide thumbs Also See for CTS-3010:
Table of Contents

Advertisement

Chapter 7
Troubleshooting the CTS 1300
Step 5
Adjust the camera mounting plate to center the red plus sign on the display inside the black plus sign on
the target.
The screws that you use to adjust the camera are shown in
The top two screws provide adjustment to the right and left. Use a 2.5 mm Allen wrench for these
screws.
The lower screw provides up and down adjustment. Use a 2.5 mm Allen wrench for this screw.
The screws in the middle adjust the camera rotation. Use a 3 mm Allen wrench for these screws.
Figure 7-75
Side to side
adjust screw
Step 6
Adjust the camera zoom by completing the following steps:
a.
Loosen the thumbscrew for the zoom ring on the camera lens.
Note
Align and center the camera by competing the following steps:
b.
After you adjust the zoom, make any required adjustments to the focus with the focus ring.
c.
OL-13676-04
Camera Adjustment Screws
Left
adjust
screw
Up/down
adjust
screw
The zoom ring is labeled "W-T".
Align the black curved line on the right of the target until it touches the right side of the display
screen.
Center the black cross on the target with the red cross on the display screen.
Figure
7-75.
Right
adjust
screw
Up/down
adjust
screw
Cisco TelePresence System Release 1.6 Administration Guide
Managing Hardware Setup
Side to side
adjust screw