Item
Operating ambient temperature
*1
Storage ambient temperature
Operating ambient humidity
Storage ambient humidity
Vibration resistance
Shock resistance
*6
Operating atmosphere
*3
Operating altitude
Installation location
*4
Overvoltage category
*5
Pollution degree
Cooling method
Grounding
*1 The operating ambient temperature indicates the temperature inside the enclosure of the control panel to which the GOT is installed.
*2 When any of the following units is mounted, the maximum operating ambient temperature must be 5°C lower than the one described in
the general specifications.
GT27:
Multimedia unit (GT27-MMR-Z)
MELSECNET/H communication unit (GT15-J71LP23-25, GT15-J71BR13)
CC-Link communication unit (GT15-J61BT13)
Protective cover for oil
GT25 (Except for GT25-W, GT2505-V):
MELSECNET/H communication unit (GT15-J71LP23-25, GT15-J71BR13)
CC-Link communication unit (GT15-J61BT13)
Protective cover for oil
GT25-W, GT2505-V:
Protective cover for oil
*3 Do not use or store the GOT under the atmospheric pressure higher than that at an altitude of 0 m.
Doing so may cause a malfunction.
Air purging by applying pressure to the control panel may create clearance between the surface sheet and the touch panel. This may
cause the touch panel to be not sensitive enough or the sheet to come off.
Specifications
*2*7
0 °C to 55 °C
-20°C to 60°C
*8
10% RH to 90% RH,
*8
10% RH to 90% RH,
Compliant with JIS B 3502 and
IEC 61131-2
Under intermittent
vibration
Under continuous
vibration
Compliant with JIS B 3502 and IEC 61131-2 (147 m/s
No greasy fumes, corrosive gas, flammable gas, excessive conductive dust, and direct sunlight (as well as at storage)
2000 m or less
Inside control panel
II or less
2 or less
Self-cooling
Grounding with a ground resistance of 100 Ω or less by using a ground cable that has a cross-sectional area of 2 mm
more. If impossible, connect the ground cable to the control panel.
Frequency
Acceleratio
n
5 Hz to 8.4 Hz
8.4 Hz to 150
9.8 m/s
Hz
5 Hz to 8.4 Hz
8.4 Hz to 150
4.9 m/s
Hz
2
(15 G), 3 times in each X, Y, or Z direction)
3.1 General Specifications
Half
Sweep
amplitude
count
3.5 mm
X, Y, or Z
10 times in
2
each
direction
1.75 mm
2
2
or
3 SPECIFICATIONS