Smart Power Supply Error Code 8 Flow Chart 1L "Motor Controller Fault Signal (8) - GE T2100-ST1 Service Manual

Hide thumbs Also See for T2100-ST1:
Table of Contents

Advertisement

Troubleshooting
Smart Power Supply Error Code 8 Flow Chart 1L "Motor
Controller Fault Signal (8)"
1Q
Is the Red LED D13
flashing 8 times with 4
second pause on the
Smart Power Supply
PCBLF0443-1?
Yes
Turn the treadmill power
switch OFF (O).
Verify the harness between Drive PC2303-012-N
and Smart Power Supply PCBLF0443-1 is properly
connected.
Verify the harness between Motor
00101-03 and Drive PC2303-012-N is properly
connected.
Send a Start Belt Command or
Press Start if equipped with
controller.
No
Replace Drive
PC2303-012-N
Return Treadmill
to service.
96
No
PMC5FA-
Did the running
belt start?
Yes
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
Yes
Go To
Page 1I
Is the Red LED D13
flashing on the Smart
Power Supply
PCBLF0443-1?
Was the harness
properly
connected?
Yes
Was the harness
properly
connected?
Yes
Turn the treadmill power
switch ON (-).
Is the Red LED D13 on
Yes
the Smart Power
Supply PCBLF0443-1
on continuously?
No
Treadmill should
be operational.
No
Connect harness.
No
Connect harness.
No
Go To
Page 1I
2097937-002 Rev G
11 March 2019

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T2100-st2