Smart Power Supply Error Code 4 Flow Chart 1M "Over Speed Motor Controller Error (4); March - GE T2100-ST1 Service Manual

Hide thumbs Also See for T2100-ST1:
Table of Contents

Advertisement

Smart Power Supply Error Code 4 Flow Chart 1M "Over Speed
Motor Controller Error (4)"
1M
Is the Red LED D13
flashing 4 times with 4
second pause on the
Smart Power Supply
PCBLF0443-1?
Yes
Turn the treadmill power switch
OFF (O) for 10 seconds then turn
the power switch ON (-).
Is the Red LED D13 on
No
the Smart Power
Supply PCBLF0443-1
on continuously?
Go To
Page 1I
2097937-002 Rev G

11 March 2019

No
Yes
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
Yes
Go To
Page 1I
Is the Red LED D13
flashing on the Smart
Power Supply
PCBLF0443-1?
Send a Start Belt Command or Press
Start if equipped with controller
increase speed to 10mph.
With the treadmill
running at 10.0 mph
for 1 minute, is the
Red LED D13 on?
Yes
Return Treadmill
to service.
Troubleshooting
No
Treadmill should
be operational.
No
Replace Drive
PC2303-012-N