Incoming Power 110-240VAC Flow Chart 1A

1A
Verify Nameplate Voltage for
proper treadmill operating
power. 110-120VAC or
220/240VAC.
Verify power panel circuit
breaker is turned on and
voltage is available at wall
receptacle.
Verify available power and
treadmill voltage requirements
are compatible.
Verify treadmill power switch is
in the off (0) position.
Verify the power cord is
plugged in treadmill circuit
breaker, and then plug power
cord into dedicated circuit
wall receptacle.
Turn treadmill power switch is
in the on (1) position.
Is the green
power circuit
breaker lit?
Yes
Go To
Chart 1B
78
Turn treadmill power switch
to the off position (0).
Disconnect power cord from
treadmill and wall outlet.
Measure continuity thru the
20amp circuit breaker.
Verify the power cord is
plugged in treadmill circuit
breaker, and then plug power
cord into dedicated circuit
wall receptacle.
No
Turn treadmill power switch in
the on (1) position.
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
Check power
Yes
cord for
damage?
No
Circuit
No
breaker has
continuity.
Yes
Is the green
No
power circuit
breaker lit?
Yes
Go To
Chart 1B
Replace power
cord.
Replace 20amp
Circuit Breaker.
Verify power from
power panel.
2097937-002 Rev G